pynetdicom.pdu.A_ABORT_RQ¶
-
class
pynetdicom.pdu.
A_ABORT_RQ
[source]¶ An A-ABORT-RQ PDU.
An A-ABORT-RQ PDU is used to abort the association.
-
pdu_length
¶ The number of bytes from the first byte following the PDU Length field to the last byte of the PDU.
- Type
Notes
An A-ABORT-RQ PDU requires the following parameters:
PDU type (1, fixed value,
0x06
)PDU length (1, fixed value, 4)
Source (1)
Reason/Diagnostic (1)
Encoding
When encoded, an A-ABORT-RQ PDU has the following structure, taken from Table 9-26 (offsets shown with Python indexing). PDUs are always encoded using Big Endian.
Offset
Length
Description
0
1
PDU type
1
1
Reserved
2
4
PDU length
6
1
Reserved
7
1
Reserved
8
1
Source
9
1
Reason/Diagnostic
References
DICOM Standard, Part 8, Section 9.3.8
DICOM Standard, Part 8, Section 9.3.1
Methods
__init__
()Initialise a new A-ABORT-RQ PDU.
decode
(bytestream)Decode bytestream and use the result to set the field values of the PDU.
encode
()Return the encoded PDU as
bytes
.from_primitive
(primitive)Setup the current PDU using an A-ABORT or A-P-ABORT primitive.
Return an A-ABORT or A-P-ABORT primitive from the current PDU.
Attributes
Return the PDU Length field value as an int.
Return the PDU Type field value as
int
.Return a str description of the Reason/Diagnostic field value.
Return a str description of the Source field value.
-
from_primitive
(primitive)[source]¶ Setup the current PDU using an A-ABORT or A-P-ABORT primitive.
- Parameters
primitive (pdu_primitives.A_ABORT or pdu_primitives.A_P_ABORT) – The primitive to use to set the current PDU field values.
-
property
pdu_length
¶ Return the PDU Length field value as an int.
-
property
reason_str
¶ Return a str description of the Reason/Diagnostic field value.
-
property
source_str
¶ Return a str description of the Source field value.
-