Non-Patient Object Storage Service Class¶
The Non-Patient Object Storage Service Class defines a service that facilitates the transfer of non-patient related information to another AE.
Supported SOP Classes¶
| UID | SOP Class |
|---|---|
| 1.2.840.10008.5.1.4.38.1 | HangingProtocolStorage |
| 1.2.840.10008.5.1.4.39.1 | ColorPaletteStorage |
| 1.2.840.10008.5.1.4.43.1 | GenericImplantTemplateStorage |
| 1.2.840.10008.5.1.4.44.1 | ImplantAssemblyTemplateStorage |
| 1.2.840.10008.5.1.4.45.1 | ImplantTemplateGroupStorage |
| 1.2.840.10008.5.1.4.1.1.200.1 | CTDefinedProcedureProtocolStorage |
| 1.2.840.10008.5.1.4.1.1.200.3 | ProtocolApprovalStorage |
Statuses¶
C-STORE Statuses¶
| Code (hex) | Category | Description |
|---|---|---|
| 0x0000 | Success | Success |
| 0x0112 | Failure | SOP Class not supported |
| 0x0117 | Failure | Invalid object instance |
| 0x0124 | Failure | Not authorised |
| 0x0210 | Failure | Duplicate invocation |
| 0x0211 | Failure | Unrecognised operation |
| 0x0212 | Failure | Mistyped argument |
Non-Patient Object Storage Service Statuses¶
| Code (hex) | Category | Description |
|---|---|---|
| 0xA700 | Failure | Out of resources |
| 0xA900 | Failure | Dataset doesn’t match SOP Class |
| 0xC000 | Failure | Cannot understand |
pynetdicom Statuses¶
When pynetdicom is acting as a Non-Patient Object Storage SCP it uses the following status codes values to indicate the corresponding issue has occurred to help aid in debugging.
| Code (hex) | Category | Description |
|---|---|---|
| 0xC001 | Failure | User’s callback implementation returned a status Dataset with no (0000,0900) Status element |
| 0xC002 | Failure | User’s callback implementation returned an invalid status object (not a pydicom Dataset or an int) |
| 0xC210 | Failure | Failed to decode the dataset received from the peer |
| 0xC211 | Failure | Unhandled exception raised by the user’s
implementation of the on_c_store callback |
References¶
- DICOM Standard, Part 4, Annex GG
- DICOM Standard, Part 7, Section 9.1.1.1.9